pi lit® Sequential Safety Flare – Quick Start Guide Summer 2023 Update.pdf
pi -lit® Sequential Safety Flare – Quick Start Guide
IMPORTANT: A TAP is a momentary press; a hold is a 3-second press!
● Battery Status
o When Flare is OFF, press for 3 seconds the square π (pi) button.
o A yellow/green LED will begin to flash
▪ 5 yellow = full batteries, 4 yellow = good batteries, 3 yellow, 2 red = low batteries, 1 red = batteries depleted (time to change batteries)
● Turning on Flares – Rapid Deployment System (RDS) – Simply pull off case! (Rechargeable only)
OR,
o Briefly TAP either button.
▪ Yellow/Green LED will illuminate indicating that the flare is turning on.
▪ First flare takes approximately 3 seconds to turn on
▪ The remaining flares will take approximately 1 sec to turn on
o IMPORTANT: wait until the flare begins to flash before turning on or pulling off the next flare in line.
● Tilt Sensor – Choice of LEDs – Locking Orientation of LEDs
o There are 16 LEDs on the SIDE of the flare and 4 LEDs on the TOP.
o The flare has a tilt sensor: When placed flat on a surface the side LEDs flash. When magnetically attached to a vehicle, vertical panel, or when on its edge, the “top” LEDs will flash.
o To disable the tilt sensor, simply TAP the square π (pi) button while the flare is operating. This will send the command to all the flares to “lock” on the 4 TOP LEDs even if it is in the HORIZONTAL position. TAP the square π (pi) button again and the 16 side LEDs will be locked on (irrespective of orientation). The 3rd TAP of the square π (pi) button will bring the flare back to its default state where the tilt sensor controls the choice of LEDs.
● Changing Patterns
o To change patterns, simply TAP the round power button on any flare that is flashing.
▪ 2 Sequential Flashing Patterns, 1 Simultaneous Flash Pattern, 1 Steady Glow Flash Pattern.
● Reverse Sequence: With flares on, momentarily TAP both buttons simultaneously on any flare. This will reverse the sequence
o This is stored into memory. Allows for reverse deployment technique.
● Disabling and Activating “PAIR” Mode
o “PAIR” Mode is activated every time the flares are turned on (indicated by blinking RED indicator LED)
o To disable or turn off “PAIR” mode, from any flare in the group, HOLD both the power and pi button for 3 seconds. Green LED will blink twice and RED LED will stop blinking.
o To activate “PAIR” mode, from any flare in the group, HOLD both the power and pi button for 3 seconds. RED LEDs on all flares in the group will begin to blink.
● Turning OFF the Flares
o There are two ways of turning OFF the flares:
▪ To turn off all the flares: Press and HOLD the power (round) button for 3 seconds. All the flares will turn off and a red LED will flash for a few seconds to indicate the flare is turning off.
▪ To turn off a single flare: Press and HOLD the square pi button for 3 seconds.
● NEW FEATURE: MAX BRIGHTNESS MODE:
○ Increase the flare's brightness (comprising battery life 10 hours).10-15 hours pattern dependent)
■ From any flare in the group, while the flares are on, HOLD both the power and pi button for 7 seconds.
■ RED Indicator LED will glow steady. Continue to hold until the GREEN indicator LED turns on. Once GREEN LED turns on, let go of the HOLD.
● Two Flashes (RED + GREEN LED) = MAX Brightness (
● One Flash (RED + GREEN LED) = Normal Brightness (~17-28 hours pattern dependent)
Pi Variables, Inc. dba pi-lit products are protected by one or more of the following U.S. and foreign patents:
| United States: | United Kingdom: | European Community: |
|---|---|---|
| 8,154,424 | 3218887 | 004142503-0001 |
| 9,847,037 | 90028382270001 | 004142503-0002 |
| 8,564,456 | 90041425030001 | 004142503-0003 |
| 9,288,088 | 90041425030002 | 004142503-0004 |
| 10,536,519 | 90041425030003 | 3218887 |
| 10,443,828 | 90041425030004 | 002838227-0001 |
| 10,551,014 | Italy: | Belgium: |
| 11,162,650 | 502020000119114 | 3218887 |
| 11,313,546 | Sweden: | Switzerland: |
| D778,752 | 3218887 | 3218887 |
| D778,753 | Australia: | Germany: |
| D854,437 | 366289 | 60 2015 060 604.3 |
| D854,438 | Canada: | Ireland: |
| 9,835,319 | 165009 | 3218887 |
| Japan: | ||
| 6776251 | ||
| 7214641 | ||
| 1609250 |
Additional patents pending:
Japan; 2021-006700; 2022-087345 – Published
Hong Kong; 40023942A; 40019830
U.S.A.; WO2016/077812; 17/513,319; 17/728,920 – Published
China; 110770082 - Published
European Union; 3580094 - Published
Additional patents pending not yet published.
!
| Power Button | (π)“pi”Button |
|---|---|
| TO TURN ON • PULL OFF CASE (Rechargeable Lithium only) • TAP Power or (π)“pi”Button (Alkaline batteries) | DYNAMIC TILT SENSOR ENABLED (Default) • TAP 1 - Locks TOP LED - 4 Total • TAP 2 - Locks SIDE LED - 16 Total • TAP 3 - Return to Dynamic Tilt Sensor Enabled |
| TAP – FOR PATTERN CHANGE FLARE(SAVED INTO MEMORY) • 1-Wave Slow/Smooth Pattern • 2-Rapid March(Quick Flash) • 3-All Flares Flash Simultaneously • 4-Steady Burn | HOLD 3 SEC.-BATTERY STATUS CHECK • IMPORTANT-Flare Must Be Off |
| Power+ (π)“pi”按钮Simultaneously | Power Off |
| TAP – REVERSE SEQUENCE • Sequence Reversed(saved in memory) | HOLD POWER BUTTON 3 SECONDS • Individual Flare Off |
| HOLD 3 SEC-ENTER/EXIT PAIR MODE-START A NEW GROUP • Center RED LED Blink = Pair Mode On • Center RED LED not Blinking=Pair Mode Off | HOLD (π)“pi”按钮3 SECONDS • Flare Group Off(turn off string of flares) |
| NEW! HOLD BOTH (π)+POWER BUTTON5 SECONDS-MAX BRIGHTNESS MODE(ONE FLARE SETS ALL PAIRRED FLARES) • Center RED LED STEADY ON-HOLD TILL GREEN LED TURNS ON THEN LET GO |